CoNextions device versus L-O suture repair for flexor tendon lacerations
Official title: Clinical Analysis of a Novel Flexor Tendon Repair Technique, A Prospective Randomized Trial
Run by Orlando Health, Inc. · NCT07068880 · Data updated 2026-11-22
This trial will test whether the CoNextions tendon repair device or the standard L-O suture repair leads to fewer ruptures and complications in adults aged 22 and older with Zone 2-5 flexor tendon lacerations.
Quick facts
| Study type | Observational |
|---|---|
| Ages | 22 Years to 88 Years |
| Sex | All |
| Enrollment | 128 (estimated) |
| Sponsor | Orlando Health, Inc. Academic / other |
| Locations | 1 site (Orlando, Florida) |
| Status | Recruiting |
| Started | June 18, 2024 |
| Main results expected | January 2027 |
| Study ends | July 2027 |
| Registry record updated | July 16, 2025 |
| Trial ID | NCT07068880 on ClinicalTrials.gov |
Is this trial a fit for you?
✓Likely a good fit
Adults aged 22 and older with acute Zone 2-5 flexor tendon lacerations who have not had prior surgery on the injured extremity and have no contraindications like metal allergy or active infection.
✕Probably not a fit
Patients under 22, those with Zone 1 injuries, prior surgery on the injured limb, active infection, inadequate blood supply, metal allergies, or incompatible metal implants would not be eligible and are unlikely to benefit.
A plain-English reading of the study's rules. Only the study team can confirm whether you qualify.
What this trial studies
This observational comparison follows adults with Zone 2-5 flexor tendon lacerations who receive either the CoNextions tendon repair device or the standard L-O suture repair. Investigators will track tendon failures, ruptures, and other complications during surgery and at 2-week, 6-week, 3-month, and 6-month follow-ups. The study collects both objective measures (rupture/failure rates) and patient-reported outcomes to characterize functional recovery. Enrollment excludes patients with prior surgery on the injured limb, metal allergies, active infection, inadequate blood supply, or other contraindications.
Why it matters
Potential benefit: If successful, the CoNextions device could reduce tendon rupture rates and lower the need for repeat surgery or prolonged immobilization.
How similar studies have gone: Standard suture repairs like the L-O technique are well established, while the CoNextions device represents a relatively new approach with limited published clinical outcome data.
Who can join: the full rules
Show full inclusion / exclusion criteria
Inclusion Criteria: * Study subjects aged 22 and older. * Subjects who sustained a Zone 2-5 flexor tendon lacerations Exclusion Criteria: * Subjects under the age of 22 at the time of consent * Subjects who sustained a Zone 1 flexor tendon injury * Subjects who have had previous surgical procedures on the injured upper extremity. * Subjects who have metal allergies * Ischemia, blood supply compromise, and/or inadequate wound coverage * Prior or current infections at or near the implant site * Conditions which tend to limit the patient's ability or willingness to restrict activities or follow directions during the healing period * Foreign-body sensitivity * The physical contact of the CoNextions TR Tendon Repair System with metal implants made of anything other than the implant grade of stainless steel, such as titanium, titanium alloys, cobalt chromium, or other dissimilar metals * Surgical procedures other than for the following indication: digital flexor tendons, digital extensor tendons proximal to the metacarpophalangeal joints (Zones 6-8) * Tendon size or surgical site access outside of specified range (Tendon Width (3.0-9.0 mm), Tendon Thickness (1.5-4.0 mm), Minimum Surgical Site Access (20 mm \[10mm/side\]) for the CoNextions TR Tendon Repair System
Where it's running
-
Orlando Health
Orlando, Florida, United States Recruiting
Study contacts
- Study coordinator: Brett Lewellyn, MD
- Email: Brett.Lewellyn@orlandohealth.com
- Phone: 321-843-5851
Similar studies
Other studies for the same condition or treatment. Recruiting studies are listed first.
-
Virtual reality rehab with early active mobilization after flexor tendon repair
This study tests whether adding virtual reality–based rehabilitation to an early active mobilization plan helps people recover finger movement, strength, and less pain after flexor tendon repair.
-
Wrist position in a 3D-printed dorsal blocking splint after flexor tendon repair
This trial tests whether three wrist angles (30° extension, neutral, or 30° flexion) in a 3D-printed dorsal blocking orthosis affect recovery after zone I–II flexor tendon repair in adults.
-
Rehabilitation comparison after thumb flexor tendon repair
This tests whether starting early active motion or keeping the thumb in a plaster cast for four weeks works better after surgery for a torn thumb flexor tendon in people older than 15.
-
Comparing human bone screws to metal screws for flatfoot surgery
This study is testing if a new human bone screw works as well as a traditional metal screw for treating flatfoot surgery to see if it can help patients recover better without needing to remove the hardware later.
-
Ultrasound-Guided Saline Injections to Prevent Tendon Scar After Finger Tendon Repair
In adults with zone II flexor tendon injuries in the fingers, researchers will test whether adding ultrasound-guided saline injections after surgery helps prevent or reduce scar tissue and improve movement.
How to take part
- Review the eligibility criteria above with your treating physician.
- Check the official listing on ClinicalTrials.gov for the latest contact details and recruitment status.
- Contact the study coordinator or principal investigator to ask for pre-screening. Pre-screening is free and never obligates you to enroll.